Glass Bead Sterilizer

For use in Biotechnology/Tissue Culture research and production. These are compact Stainless Steel units, and can be placed on Laminar Air Flow Benches. Glass Bead Sterilizers are a quick, Easy and Accurate alternative to traditional methods of sterilization. It destruct all micro organizam within seconds. The unit is ready within 30 minutes after switching on and ensure total sterilization.Jhese are incorporated with an imported thermostat, which maintains the set temperature with an.accuracy of 1 of the preset temperature range

 

HPLC System

Our HPLC System is precisely engineered in conformity with global standard. It is widely acknowledged for dimensionally accurate, compact designs, easy operation and heat resistant. Our collection finds wide application in laboratory, research institute and many others.

Isocratic Pump

Following are the technical specifications of isocratic pump:

  • Flow: 0. 01-10mL/min / 0.001-9.999
  • Max. Pressure: 40MPa
  • Dual Piston designed with main and auxiliary pump heads connected in series

Intuitive operating using simple keypad allows easy chose functions as follow:

  • Flow rate
  • Maximal flow rate – PURGE (for priming and washing)
  • Low pressure
  • High pressure limit
  • Pulsation compensation on-off
  • Pressure unit (PSI,Mpa or bar)
  • Control mode (by keypadm RS 232 or using voltage)
  • Display brightness
  • Possibility to use this pump by high pressure gradient mode, where are two three or four unit controlled from PC using RS232 or voltage

UV-VIS Variable Wave Detector

Our highly efficient UV-VIS variable wave detector is precisely engineered as per the industry standard. Following are specifications of the detector:

  • Detector Wavelength Range : 190-600 nm (Optional:600-800nm)
  • Noise Level: +/-0.3 x 10-5 AU
  • It may be used for analytical chromatography as well as preparative chromatography
  • Reference and sample signals available for detector diagnostics as well as information on lamp operating hours
  • Out put signal is both digital and analogue
  • It is possible to control the unit using the keypad or an RS232 interface
  • D2 lamp in a special socket that enables easy changing
  • Wavelength can be programmatically changed
  • Automatic Wavelength Calibration.

Karl Fisher Titrimeters

Salient Features

  • Auto Titration Control
  • Auto Zero Burette
  • Visual & Audible Alarm
  • Adjustable Timer


Melting Point Apparatus

Salient Feature

  • Fully Automatic
  • Latest Technology
  • Range upto 350oC
  • Highly Accurate
  • No Silicon Oil/ Heating Media Required

Digital Automatic Melting Point Apparatus is designed for quick and accurate detection of melting point. Feature packed & easy to use, this is an indispensable bench top tool. This equipment has an arrangement to hold the capillary containing the sample in uniformly heating media. the temperature is indicated on a digital display readable in 1.0oC. At the point, whn the sample melts, the heating is automatically cut-off and the digital display showing the temperature remains on the indicator till it is cleared. No Silicon oil or other bath is required as heating media. Range 2.0oC above room temperature to 350oC.


Moisture Titrator

We design and fabricate precision engineered Karl Fischer moisture titrator. Available in various specifications, the titrator can be customized in accordance with client requirements. Featured with compact designs, easy operation and efficiency, our assortment has received wide accolade in diverse industries.



Mortuary Chamber

Used for storing cadaverous under low temperature cool conditions in order to prevent decomposition. These units are double walled with outer made of M.S. Sheet duly painted and inner walls of S.S. Trays made of G.!. Sheet to carry dead bodies are provided with handles so as to carry dead bodies. Trays travel on rollers fitted with ball \- bearings for easy movement. Hermetically sealed compressor serves refrigeration unit, to maintain temperature range of -2° C to 5° C or -15° C to -20° C (as ordered) Unit is fitted with Digital Temperature Indicator-cum Controller. To work on 220/230 voltsA.C. Supply.



Photo Colorimeter

Salient Features

  • 1 ml. Solution measurements
  • Standard Glass Filters
  • Highly Stable & Accurate


Tablet Hardness Tester

We specialize in designing and developing precision engineered tablet hardness tester. Our tester can be fitted on either bench or tablet ling machine. It is offered with various precision engineered components including engineered Dial Gauge, Aluminium Body and others. Follow pointer records force on Dial Gauge while main pointer goes back to zero.

Specification :

  • Capacity 0-200 Newtrons
  • Accuracy + 5 Newtrons


TDS METERS

Salient Features

  • Highly Stable and Accurate
  • Cell Constant Adjustment Facility
  • Available in Lab & Field models
  • Temperature Coefficient Correction facility


Tissue Flotation Bath

Double walled, inside made of Aluminum steel duly black painted and outside made of Mild Steel Sheet duly power coated Thermostatic control from ambient temp. to 80DC :t 1 DC complete with indicators, cord & plug to work on 220/230V AC. without thermometer.

Air Conditioner Module

It is useful in Front of Air Conditioner to provide a sterile, bacteria free & dust free Air of 0.3 microns in a particular temperature . It works on the Laminar Air Flow Principle .

SPECIFICATIONS:- Sizes Available asper the size of A.C. (Window/split type)


Ultrasonic Bath (Sonicator)

Salient Features

  • Easy to operate & made of one piece S. S. Tank
  • Indigenously manufactured with advanced MOSFET technology, with
  • Auto-tuning facility
  • Compact, rugged and highly durable systems
  • Extensively protected electronic circuits means longer and safer operations
  • Digital tuning of Transducers with Generators to avoid any frequency shifted even during demanding applications

UV-VIS Spectrophotometer

Our company offers wide range of UV-VIS spectrophotometer which is fabricated in conformity with international standard. The collection is also designed and developed in accordance with the client specifications and requirements. It finds application in laboratories, research institutes, textile & leather industry and many others.

Its applications are in determination of :

  • Nutrients like N, P, K, S, Ca, Mg, Zn, Cu, B, Mo etc., in Agricultural soil, plants and others
  • Organic components in Plants and Biological matter
  • Glucose, fructose, carbohydrates, proteins etc, in foods
  • Edible dyes alcohols etc., in beverages
  • Purity of constituents in pharmaceuticals
  • Toxic elements Cd, Pb, Hg etc., in effluents
  • Constituents in compositions used in metallurgy, fertilizer, pesticide, chemical,
  • Petrochemical, steel, cement, glass & other industries.

Water & Soil Analysis Kit

We specialize in designing and fabricating superior quality water and soil analysis kit. It is made available to our clients with 3 ½ digit LCD Display. Our efficient kits are mains cum battery operated. It gives accurate result for soil and water analysis. Some of the salient features of our range:

  • Measures pH, mV, Conductivity
  • TDS, DO, Temperature & Turbidity
  • Housed in VIP Briefcase